Experiments
Searchable full-text extractions: founding hypothesis, core claims, experimental setups, key results and statistics — pulled out of each paper as structure. Search a cell line, an assay or an entity (e.g. HUH7) and find every paper that worked with it. This corpus stands on its own: most entries carry no reproduction assessment (yet).
-
Full-text index only
A novel wavelet-based thresholding method for the pre-processing of mass spectrometry data that accounts for heterogeneous noise.
PMID 18615428 · PMC2855839 · Proteomics · 2008 · 6 claims · 4 setups
Noise in SELDI-TOF/MALDI-TOF mass spectrometry data is heteroscedastic across the m/z range, with larger variance at lower m/z values, contrary to the homogeneous noise assumption of existing wavelet denoising methods.
-
Full-text index only
Identification of serum biomarkers for colon cancer by proteomic analysis.
PMID 16755300 · PMC2361335 · British journal of cancer · 2006 · 8 claims · 8 setups
Complement C3a des-arg, α1-antitrypsin and transferrin were identified as serum proteins with diagnostic potential for CRC.
-
Full-text index only
Serum diagnosis of diffuse large B-cell lymphomas and further identification of response to therapy using SELDI-TOF-MS and tree analysis patterning.
PMID 18163913 · PMC2242801 · BMC cancer · 2007 · 8 claims · 8 setups
SELDI-TOF-MS serum proteomic patterns analyzed by decision tree classification (Biomarker Pattern Software) can discriminate DLBCL patients from healthy controls with high sensitivity and specificity.
-
Full-text index only
Development of proteomic patterns for detecting lung cancer.
PMID 14757945 · PMC3851077 · Disease markers · 2003 · 8 claims · 3 setups
A decision tree classification algorithm built on three serum protein mass peaks (8122Da, 1452Da, 1610Da) can discriminate lung cancer patients from healthy controls
-
Full-text index only
Sample preparation for serum/plasma profiling and biomarker identification by mass spectrometry.
PMID 17166507 · PMC7094463 · Journal of chromatography. A · 2007 · 8 claims · 8 setups
Standardizing sample preparation procedures for serum/plasma profiling is critical for obtaining reliable biomarkers, since slight procedural changes can produce very different protein profiles.
-
Full-text index only
The impact of peptide abundance and dynamic range on stable-isotope-based quantitative proteomic analyses.
PMID 18798661 · PMC2746028 · Journal of proteome research · 2008 · 8 claims · 7 setups
Over half of confidently identified peptides in complex mixtures have S/N ratios below 10 on both FT-ICR and Orbitrap instruments